Latest Success Metrics For Actual 5V0-21.21 Exam 2023 Realistic Dumps [Q24-Q40]

Share

Latest Success Metrics For Actual 5V0-21.21 Exam 2023 Realistic Dumps

Updated 5V0-21.21 Dumps Questions For VMware Exam


VMware 5V0-21.21 certification exam is designed for professionals who have experience in designing, deploying, and managing VMware vSphere and VMware vSAN solutions. 5V0-21.21 exam is an essential requirement for individuals who want to earn the VMware HCI Master Specialist certification. VMware HCI Master Specialist certification validates the expertise of professionals in delivering VMware solutions that enable organizations to streamline their IT operations and improve business agility.

 

NEW QUESTION # 24
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
  • B. Upgrade to VMware vCenter Server 7.0 U1.
  • C. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
  • D. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • E. Choose the Allow reduced redundancy option.
  • F. Disable vSAN Encryption before starting the upgrade process.

Answer: B,D,E


NEW QUESTION # 25
An administrator is setting up vSAN file services on a vSAN cluster but is unable to join the vSAN File Services to the domain.
Which two possible reasons could explain this failure? (Choose two.)

  • A. The administrator was using pre-created computer objects for the file services in the Active Directory.
  • B. The administrator wanted to register the file services to a sub-domain.
  • C. A read-only domain controller was being used.
  • D. The administrator did not pre-create a dedicated organizational unit in Active Directory.
  • E. The administrator was using IP addresses from an IP pool.

Answer: B,C

Explanation:
https://docs.vmware.com/en/VMware-vSphere/8.0/vsan-administration/GUID-CA9CF043-9434-454E-86E7-DCA9AD9B0C09.html


NEW QUESTION # 26
Which description is a valid use case for an administrator to configure an HCI Mesh?

  • A. Share storage hosted by or on a vSAN cluster to more than 64 hosts, including both local and remote hosts connected.
  • B. Share storage hosted by or on a vSAN cluster that must be applied to different vSAN SPBM policies for different client clusters.
  • C. Share storage hosted by or on a vSAN cluster, and each client vSAN cluster must mount a maximum of five remote vSAN datastores.
  • D. Share storage hosted by or on a vSAN cluster to six or more client clusters.

Answer: C


NEW QUESTION # 27
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

  • A. SFTT = 0
  • B. SFTT = 1
  • C. PFTT = 0
  • D. PFTT = 1

Answer: C

Explanation:
Primary level of failures to tolerate (PFTT). For stretched clusters, PFTT defines the number of site failures that a virtual machine object can tolerate. For a stretched cluster, only a value of 0 or
1 is supported.
Secondary level of failures to tolerate (SFTT). For stretched clusters, SFTT defines the number of additional host failures that the object can tolerate after the number of site failures defined by PFTT is reached. If PFTT = 1 and SFTT = 2, and one site is unavailable, then the cluster can tolerate two additional host failures.
The default value is 0, and the maximum value is 3.
So data mirroring across sites = PFTT
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-
planning.doc/GUID-1BDC7194-67A7-4E7C-BF3A-3A0A32AEECA9.html


NEW QUESTION # 28
An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.
Which solution mandates the use of VMware vSAN?

  • A. VMware Cloud Foundation
  • B. VMware vRealize Automation
  • C. VMware Tanzu
  • D. VMware Horizon

Answer: B


NEW QUESTION # 29
An administrator is setting up vSAN file services on a vSAN cluster but is unable to join the vSAN File Services to the domain.
Which two possible reasons could explain this failure? (Choose two.)

  • A. The administrator was using pre-created computer objects for the file services in the Active Directory.
  • B. The administrator wanted to register the file services to a sub-domain.
  • C. A read-only domain controller was being used.
  • D. The administrator did not pre-create a dedicated organizational unit in Active Directory.
  • E. The administrator was using IP addresses from an IP pool.

Answer: B,C


NEW QUESTION # 30
A vSAN architect is reviewing an RFP (Request For Proposal) that has the following vSAN Ready Nodes requirements:
- CPU upgrades every two years.
- SAS drives will be changed to NVMe drives after one year.
- Introduce additional IO controllers to enhance performance.
What should the architect consider when writing the response?

  • A. CPU upgrades requires opening a case with GSS.
    Changing the drive protocol in a vSAN Ready Node requires disk wipeout.
    Any OEM IO controller can be added.
  • B. CPU upgrades are supported.
    Changing the drive protocol in a vSAN Ready Node is not supported.
    Only tested and certified IO controllers can be added.
  • C. CPU upgrades are not supported.
    Changing the drive protocol in a vSAN Ready Node is supported.
    Any HCL certified IO controllers can be added.
  • D. CPU upgrades are supported with only specific vSAN Ready Nodes.
    Changing the drive protocol in a vSAN Ready Node is only supported with HCI appliances.
    Only OEM-provided IO controllers can be added.

Answer: B


NEW QUESTION # 31
An administrator is planning to change a vSAN Storage Policy to apply a Failures To Tolerate (FTT) of 2, using RAID-6.
What is the minimum number of vSAN nodes required?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 32
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)

  • A. The cluster DRS threshold has been set to Aggressive.
  • B. There is a vSAN node failure.
  • C. The vSAN Resync throttling is enabled.
  • D. The vSAN policy protection level has changed from FTT=0 to FTT=1.
  • E. The object repair timer value has been increased.

Answer: C,D


NEW QUESTION # 33
An administrator is setting up vSAN file services on a vSAN cluster. Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

  • A. Forged Transmits
  • B. MacLearning
  • C. DVFiltering
  • D. Jumbo Frames
  • E. Promiscuous Mode

Answer: A,B

Explanation:
MacLearning and Forged Transmits are enabled as part of the vSAN File Services enablement process for a provided DVS port group.
Reference:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan.doc/GUID- CA9CF043-9434-454E-86E7-DCA9AD9B0C09.html


NEW QUESTION # 34
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?

  • A. Restore the communication with the KMS server, and re-establish the trust relationship.
  • B. Replace the caching device in each affected disk group.
  • C. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
  • D. Manually replace the Host Encryption Key (HEK) of each affected host.

Answer: A

Explanation:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-084B3888-499F-4CD0-8954-A149560B1534.html


NEW QUESTION # 35
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?

  • A. All objects on the affected host will be lost.
  • B. A rebuild of the affected objects will occur.
  • C. All objects will remain accessible.
  • D. The cluster will be partitioned and the vSAN host will need to be rejoined.

Answer: B


NEW QUESTION # 36
An 8-Node vSAN Stretched Cluster (4+4+1) with a single disk group has a policy with PFTT=1 (mirrored across sites) and SFTT=1/FTM Mirroring (Local Protection) configured. The administrator has been alerted that there is a problem with the cluster. The following has been observed:
* The vSAN Witness Host is offline.
* Two disk failures on two hosts have occurred in the preferred site.
This has resulted in a critical production virtual machine's vmdk becoming inaccessible. Which step needs to be performed by the administrator to resolve the issue?

  • A. Replace only one failed disk on the preferred site.
  • B. Replace access to the existing vSAN Witness Host
  • C. Replace the vSAN Witness Host
  • D. Replace all failed disks on the preferred site.

Answer: B

Explanation:
The vSAN Witness Host offline and 2 failures in the Preferred Site.
In each of the above failure cases, restoring access to the existing vSAN Witness would make the object accessible.
...
Deploying a new vSAN Witness would not because the components would not be present.
https://core.vmware.com/resource/vsan-stretched-cluster-guide#sec7373-sub5


NEW QUESTION # 37
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
  • B. Choose the Allow reduced redundancy option.
  • C. Upgrade to VMware vCenter Server 7.0 U1.
  • D. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • E. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
  • F. Disable vSAN Encryption before starting the upgrade process.

Answer: E


NEW QUESTION # 38
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads. The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 -Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 -Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 -Site Disaster Tolerance=None -Keep Data on Preferred, FTT=Mirroring
* Policy 4 -Site Disaster Tolerance=None -Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site -Preferred Site workloads should run on DC1 hosts.
* Secondary Site -Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • B. Change the FTT setting in Policy 3 to be "Erasure Coding".
  • C. Change the Site Disaster Tolerance setting in Policy 4 to be "None -Keep Data on Preferred".
  • D. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • E. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".

Answer: D,E

Explanation:
A: to replicate VMs on second site
E: to move compute for those VMs on second site


NEW QUESTION # 39
A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

  • A. Delete the disk group(s) on the legacy host
  • B. Remove from vSAN cluster
  • C. Disconnect from vCenter Server
  • D. Place the host in maintenance mode with no data migration
  • E. Place the host in maintenance mode with Ensure Accessibility
  • F. Place the host in maintenance mode with Full Data migration

Answer: A,B,F


NEW QUESTION # 40
......

Full 5V0-21.21 Practice Test and 68 Unique Questions, Get it Now!: https://www.vcetorrent.com/5V0-21.21-valid-vce-torrent.html

Best Value Available Preparation Guide for 5V0-21.21 Exam: https://drive.google.com/open?id=1hPbGnXZSDWHBQwG57KVaSwjLdLpw9KaY